What's happening: The system reports a temperature sensor error on the Hashboard.

Possible causes:

  1. Power supply voltage fluctuations.
  2. Poorly connected Hashboard cables.
  3. Dirty Hashboard connectors and contacts.
  4. Faulty PSU.

What to do:

  1. Check Hashboard cable connections.
  2. Clean the connectors and contacts.
  3. Try replacing the PSU with a known good one.
  4. Turn off the miner for 10-15 minutes and turn it back on.

If the error persists, the cause might be faulty sensors on the Hashboard, requiring chip replacement. The Firmware includes a feature to operate with faulty sensors. The Ignore faulty temperature sensors function allows continued operation if it does not compromise device safety (see section Mining → Advanced).