HashCore Docs
Devices (Miners)

Cooling Management

Cooling management (Thermal config) allows you to configure cooling parameters for a single device or a group of devices. Available only for devices running HashCore Firmware.

Single Device Management v0.7.0

To change the cooling mode on a single device:

  1. Open the device context menu (⋯ button)
  2. Go to Maintenance → Change cooling mode
  3. Select the desired mode and set the parameters
  4. Click Apply

Group Management v0.9.0

For bulk changes to cooling parameters:

  1. Select devices using the checkboxes in the Workers list
  2. In the group actions panel, select Thermal config
  3. Configure the desired parameters
  4. Click Apply

Cooling Parameters

ParameterDescription
Cooling modeOperating mode: Auto, Manual, or No change
Target temperatureTarget chip temperature in °C
Fan speedFan speed in % (Manual mode only)
Min fansMinimum number of operational fans

Cooling Modes

  • Auto — the system automatically controls fan speed to maintain the target temperature
  • Manual — fan speed is set manually in %
  • Immersion — mode for devices in immersion cooling (fans are disabled)
  • No change — do not change the current mode (for group operations only)

Partial Update v0.9.0

In group mode, you can fill in only the fields you want to change. Unfilled fields do not affect the current device settings. This allows, for example, changing only the Target temperature without changing the cooling mode.

Devices running firmware other than HashCore Firmware, as well as devices in Immersion mode, are skipped during group operations and appear in the Failed tab with the reason "Not supported".